Pendampingan Radiografer dalam Quality Control Pelaksanaan Repeat Analysis di Instalasi Radiologi
Abstract
Repeat analysis is a quality assurance program regarding medical imaging to determine the cause of image repetition, as a reference for radiographers, department workflows, and ultimately reduce patient dose (Atkinson et al, 2020). Based on the decision (Minister of Health Number 129/Menkes/SK/II/2008), the standard for radiographic image rejection is ≤ 2%. Most radiology installations have not implemented a comprehensive repeat analysis program so that the repeat rate has increased or decreased. The service team wants to provide assistance regarding the calculation, analysis and evaluation of repeat analysis and provide motivation to partners to routinely carry out quality assurance programs through socialization and mentoring to maintain service quality. The repeat analysis quality assurance program already exists but has not been routinely evaluated, March-May 2025 although still within normal limits (≤ 2%), the repeat rate increased from 0.8%, 1.17% and 1.23%, an average of 1.07%. The factors causing repeats were cut by 80%, movement by 13.3% and position by 6.67%. To minimize this, it is best to carry out periodic analysis and evaluation and look for causes and solutions.
Keywords
Full Text:
PDFReferences
Amaliya, S.F., et al (2025). Sistematik review perbandingan antara MRI dan PET/CT dalam mendeteksi metastasis kelenjar getah bening pada kanker serviks.Healthy jurnal Inovasi Riset Ilmu Kesehatan, 4 (2).121. https://doi.org/10.51878/healthy.v4i2.5873
Anif Chafidin, & Suraningsih (2019). Analisis Pengulangan Citra Digital dengan menggunakan digital radiography di instalsi radiologi Rumah Sakit Panti Waluyo Surakarta. Jurnal Pijar MIPA, 14(1), 1-12
Artitin C, (2022). Analisa pengulangan (repeat) Radiograf di unit Radiologi Rumah Sakit Umum Daerah Mohammad Natsir Solok. Jurnal Teras Kesehatan 5(1), 25-30. https://doi.org/10.38215/jtkes.v5i1.72
Atkinson, S., Neep, M. and Starkey, D. (2020) ‘Reject rate analysis in digital radiography: an Australian emergency imaging department case study’, Atkinson et al., 2020, 67(1), pp. 72–79. Available at: https://doi.org/10.1002/jmrs.343
Depkes RI. Kepmenkes 129 tahun 2008. standar pelayanan minimal rumah sakit. 2008
Hariri, (2018), Standar Nasional Akreditasi Rumah Sakit, Edisi 2
Kemenkes. Kemenkes no 1250 tahun 2009 tentang kendali mutu (quality control) peralatan radiodiagnostik. 2009
Papp J. Quality management in the imaging sciences e-book. Elsevier Heal Sci. 2019
Soularto, D.S., et al.(2022), Digital system pelaporan insiden keselamtan pasien di Rymah Sakit. Prosiding seminar nasional Program Pengabdian Masyarakat. https://doi.org/10.1018196/ppm.43.635
Weatherburn, G.C., Bryan, S. and West, M. (2014) ‘A comparison of image reject rates when using film, hard copy computed radiography and soft copy images on picture archiving and communication systems (PACS) workstations’, British Journal of Radiology, 72(JUL.), pp. 653–660. Available at: https://doi.org/10.1259/bjr.72.859.10624322
Yoshandi TM, Sayuti A, Bisra M. Analisa Pengulangan (Repeat) Citra Radiografi Di Unit Radiologi Rumah Sakit Awal Bros Panam Pekanbaru. J Hosp Adm Manag. 2020;1(2).
DOI: https://doi.org/10.31004/abdira.v6i3.1185
Refbacks
- There are currently no refbacks.
Copyright (c) 2026 Siti Rosidah

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.