Pendampingan Radiografer dalam Quality Control Pengujian Kolimator di Instalasi Radiologi RS Bhayangkara Semarang
Abstract
One of the quality assurance programs is collimator testing on X-ray aircraft. According to KMK no. 1250 of 2009 Collimator testing on Sinr-X aircraft is carried out once a month. The Bhayangkara Hospital Radiology Installation already has a quality assurance program for radiography equipment, however collimator testing on aircraft is not carried out routinely, most recently in August 2020 when the X-ray aircraft was installed and when licensing was to be carried out. The service team wants to provide conformity testing services related to collimator testing and provide motivation to partners to routinely carry out equipment quality control programs through socialization and assistance in conformity testing of X-ray aircraft collimators in accordance with KMK No. 1250 concerning quality control. The research results show that a quality control program for X-ray aircraft already exists but has not been carried out routinely, the results of collimator field area testing experienced deviations that were still within the normal limit below the standard, namely less than 2%. To ensure that the X-ray aircraft is in good condition and to ensure that the radiation dose to the patient does not occur again, a quality control program should be carried out periodically.
Keywords
Full Text:
PDFReferences
BAPETEN, Peraturan Kepala Nomor 9 Tahun 2011 Tentang Uji Kesesuaian pesawat Sinar-X Radiologi Diagnostik dan Intervensional, diakses dari, Http://Www.bapeten.ac.id/perka-nuklir-bapeten-no-9-tahun-2011.htm, diakses pada tanggal 6 November 2014
BAPETEN, Peraturan Kepala Nomor 15 Tahun 2014 Tentang Keselamatan Radiasi Dalam Produksi Pesawat Sinar-X Radiologi Diagnostik Dan Intervensional.
Bushong, Steward. 2016. Radiologic Science For Technologists Physics, Biology And Protection.Mosby :USA (hal. 228)
Fauber, T. (2016) Radiographic Imaging and Exposure, Radiographic Imaging and Exposure. Elsevier Inc
Frank, Eugene. 2017. Merrill’s Atlas Of Radiographic Positioning & Procedures.Edisi 11.Mosby : USA
Fransiska, E., Nehru, N. and Afrianto, M.F. (2018) ‘Uji Kesesuaian Berkas Sinar-X Dengan Berkas Kolimator Pada Pesawat Sinar-X Di Instalasi Radiologi Rsud Raden Mattaher Jambi’, Komunikasi Fisika Indonesia, 15(1), p. 77. Available at: https://doi.org/10.31258/jkfi.15.1.77-83
KEMENKES, surat keputusan No. 12 Tahun 2009 Tentang Pedoman Kendali Mutu (Quality Control), diakses dari Http://Www.kemenkes.ac.id/KMK-1250-tahun-2009-tentang-kendali-mutu.htm, diakses pada tanggal 6 November 2014.
Papp, Jefrey. 2011. Quality Management In The Imaging Sciences.Mosby : USA
Papp, Jefrey. 2019. Quality Management In The Imaging Sciences.Mosby : USA
Pro-Project, Pro-Alpha Phantom diakses dari http://www.pro-project.pl/en/radiography-fluoroscopy/item, diakses pada tanggal 17 Februari 2015
DOI: https://doi.org/10.31004/abdira.v4i4.500
Refbacks
- There are currently no refbacks.
Copyright (c) 2024 Siti Rosidah, Masfufatun Jamil, Nanik Suraningsih
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.